If you’re a premises operator, you must comply with regulations to provide the appropriate types of fire extinguishers. Different kinds of fires require different kinds of extinguishers, and failing to follow current UK regulations can not only put you at risk of financial penalties but also endanger the safety of people working or living in the premises.
In this guide, we will explain the types of fire extinguishers and their use cases, going through details such as correct extinguisher placement, what each colour means, and how to keep your extinguishers compliant once they are in place.
Fire Extinguisher Types Explained
There are five main types of fire extinguishers used in UK premises: water, foam, CO₂, dry powder and wet chemical. Each one is designed to put out specific kinds of fire. Using the wrong one can spread the flames or put the person holding it in danger.
The type you need depends on what could catch fire in your building. An office full of paper and computers needs a different cover from a restaurant kitchen or a workshop storing fuel.
What Are the Different Classes of Fire?
In the UK, fires are grouped into classes according to the fuel that is burning, and once you understand these classes, it becomes much easier to match the right extinguisher to each risk in your building.
- Class A: solid materials such as wood, paper, cardboard and textiles
- Class B: flammable liquids such as petrol, diesel, paint and solvents
- Class C: flammable gases such as propane, butane and natural gas
- Class D: combustible metals such as magnesium, titanium and aluminium swarf
- Class F: cooking oils and fats, usually found in deep fat fryers
Electrical fires are not given their own class because electricity is the source of ignition rather than the fuel that keeps the fire burning, which is why they need to be considered separately when you are choosing which extinguishers to use.
Types of Fire Extinguishers and Their Uses
Each type of fire extinguisher is designed for particular fire classes, so the best way to understand fire extinguisher uses is to look at what each one puts out, where you are likely to find it and the situations where it should never be used.
Water Extinguishers
Water extinguishers are used on Class A fires involving solid materials such as wood, paper, cardboard and textiles, and they work by cooling the burning material until the fire can no longer sustain itself. You will usually find them in offices, schools, shops and residential buildings where most of the fire risk comes from furniture, paperwork and fittings. Water should never be used on electrical equipment, flammable liquids or cooking oil, as it can conduct electricity back to the user or cause burning fat to erupt violently.
Foam Extinguishers
Foam extinguishers are suitable for both Class A and Class B fires, which makes them a practical choice for premises that store flammable liquids such as petrol, paint or solvents alongside everyday materials. The foam forms a layer over the surface of the burning liquid that cuts off its oxygen supply and stops flammable vapours from escaping, which is why they are common in garages, warehouses and workshops. Foam is not suitable for cooking oil fires or combustible metals, and you should avoid using it near live electrical equipment unless the extinguisher has been specifically tested and labelled as safe for that purpose.
CO₂ Extinguishers
CO₂ extinguishers are mainly used on electrical fires and Class B fires involving flammable liquids, and because they leave no residue behind, they are the standard choice for offices, server rooms and any area with a lot of computers or electrical equipment. They work by displacing the oxygen around the fire, but they do very little to cool the material that was burning, so there is a risk the fire can reignite once the gas has cleared. You should take care using them in small, enclosed rooms where the gas can build up, and always hold the extinguisher by its handle, as the horn becomes extremely cold during discharge and can cause frost burns.
Dry Powder Extinguishers
Standard ABC dry powder extinguishers can tackle Class A, B and C fires as well as fires involving electrical equipment, which is why they are often found on garage forecourts, in boiler rooms and in vehicles. The powder smothers the fire and interrupts the chemical reaction that keeps it burning, but it also creates a thick cloud that reduces visibility and can be harmful if breathed in, so powder extinguishers are not recommended for use inside offices or other enclosed spaces. Specialist powder extinguishers are also available for Class D fires involving combustible metals, and these are usually found in laboratories and industrial settings where metals such as magnesium or titanium are handled.
Wet Chemical Extinguishers
Wet chemical extinguishers are designed for Class F fires involving cooking oils and fats, making them the essential extinguisher for commercial kitchens with deep fat fryers. When the wet chemical is applied as a fine spray, it reacts with the burning oil to create a soapy layer across the surface that seals in the vapours and cools the oil at the same time. They can also be used on Class A fires, although they are rarely chosen for that purpose outside a kitchen setting.
Which Extinguisher Should You Use on Electrical Fires?
You should only use an extinguisher that carries an electrical symbol on its label, as this indicates it has been tested and is safe to use on live electrical equipment. In most cases, a CO₂ extinguisher is the safest choice, particularly in offices and areas where computers, servers and other equipment are in use. Dry powder will also extinguish an electrical fire, but because of the mess and the risk to anyone breathing it in, it is better suited to outdoor areas, plant rooms and vehicles. Wherever it is safe to do so, you should switch off the power supply before tackling the fire, and you should never use water or a standard foam extinguisher on anything that is still live. Once the power has been switched off, the fire can be treated according to the class of the material that is burning. Fires involving lithium-ion batteries, such as those in e-bikes, e-scooters and power tools, can behave very differently from ordinary electrical fires and are difficult to extinguish completely, so premises that charge or store these batteries should seek advice on specialist extinguishers.
Fire Extinguisher Colours
Every fire extinguisher in the UK has a red body, and you can tell the types apart by a coloured band or panel near the top of the extinguisher, which shows at a glance what it contains and which fires it can be used on. This system comes from the British Standard BS EN 3, which requires the coloured area to cover no more than 5% of the body, so that every extinguisher stays easy to spot as a piece of fire safety equipment while still being quick to identify in an emergency.
The table below compares the five main fire extinguisher colours with the fire classes each one covers, along with the situations where each type should never be used.
| Colour | Extinguisher Type | Fire Classes | Best Used On | Never Use On |
|---|---|---|---|---|
| Red | Water | A | Wood, paper, cardboard and textiles | Electrical equipment, flammable liquids or cooking oil |
| Cream | Foam | A and B | Solid materials and flammable liquids such as petrol and paint | Cooking oil, combustible metals or live electrical equipment unless tested and labelled as safe |
| Black | CO₂ | B and electrical | Electrical equipment and flammable liquids | Cooking oil, combustible metals or solid materials where reignition is likely |
| Blue | Dry Powder | A, B, C and electrical | Mixed fire risks, flammable gases, vehicles and plant rooms | Cooking oil or enclosed spaces such as offices, and metals, unless it is a specialist powder |
| Yellow | Wet Chemical | F and A | Cooking oils and fats in deep fat fryers | Electrical equipment or flammable liquids and gases |
You may still come across older extinguishers with a body painted entirely in one colour, as this was the standard in the UK before BS EN 3 was introduced in the late 1990s, and some premises also use water mist extinguishers, which carry a white band and can be used on a wider range of fire classes than standard water. If you are unsure what an extinguisher contains, the label on the front will always confirm its type along with the fire class symbols it has been tested against.
What Type of Fire Extinguisher Do I Need?
The type of fire extinguisher you need depends on the fire risks in your building, and the clearest way to identify them is through a fire risk assessment, which every business premises in England and Wales is legally required to carry out under the Regulatory Reform (Fire Safety) Order 2005. The assessment looks at what could start a fire, what could fuel it and who could be put at risk, and the extinguishers you choose should then match the fire classes it identifies in each part of the building.
Before choosing your extinguishers, it helps to consider:
- The materials stored or used on site, such as paper, fabrics, fuels or chemicals
- How much electrical equipment is in use and where it is located
- Whether any cooking takes place, particularly with deep fat fryers
- The size and layout of the building, including the number of floors
- Who uses the premises, whether that is staff, visitors or residents
What Fire Extinguishers Does a Small Business or Office Need?
Most small businesses and offices need a water or foam extinguisher to cover Class A fires involving paper, furniture and fittings, along with a CO₂ extinguisher to deal with any fires involving computers and other electrical equipment. Premises that also store flammable liquids, such as cleaning chemicals in larger quantities, will usually benefit from foam over water, as it covers both Class A and Class B fires.
What Fire Extinguishers Are Needed in a Commercial Kitchen?
A commercial kitchen needs a wet chemical extinguisher for any area where deep fat fryers or large quantities of cooking oil are used, as this is the only type designed to safely put out Class F fires. Most kitchens also need a CO₂ extinguisher for the electrical equipment, and a fire blanket is often recommended for smaller pan fires near the cooking area.
How Many Fire Extinguishers Does a Building Need?
The number of fire extinguishers your building needs depends on its floor area, layout and risk level. British Standard BS 5306-8 sets out a minimum level of Class A cover based on floor space and recommends at least two extinguishers on each floor in most buildings. Larger or more complex buildings will need more extinguishers, as will any areas with specific risks, such as plant rooms, kitchens or server rooms. A competent fire safety provider can determine the exact number and type needed as part of a site survey.
Which Fire Extinguisher Goes in Which Room?
Each room should have an extinguisher that matches the fire risks found there, which means an office, a kitchen and a plant room in the same building will often need different types. The table below shows the extinguishers most commonly recommended for typical rooms and areas, although your fire risk assessment should always have the final say.
| Room or Area | Main Fire Risk | Recommended Extinguisher |
|---|---|---|
| Office | Paper, furniture and computers | Water or foam, with CO₂ for electrical equipment |
| Reception and corridors | Furniture, fittings and display materials | Water or foam |
| Server room | Electrical equipment | CO₂ |
| Commercial kitchen | Cooking oil, fats and electrical appliances | Wet chemical, with CO₂ for electrical equipment |
| Staff kitchen | Small appliances and food packaging | CO₂, with a fire blanket nearby |
| Warehouse | Cardboard, pallets and stored goods | Water or foam |
| Workshop or garage | Fuels, paints and solvents | Foam, with CO₂ for power tools and machinery |
| Plant or boiler room | Electrical systems and fuel supplies | Dry powder or CO₂ |
| Vehicles | Fuel and electrical faults | Dry powder |
| Laboratory | Chemicals, gases and combustible metals | CO₂ or foam, with specialist powder for metals |
Where a room contains more than one type of risk, such as an office with a small kitchen area, you will usually need more than one extinguisher type close by so that the right one is always within reach.
Where Should Fire Extinguishers Be Placed?
Fire extinguishers should be placed on escape routes and close to exits, so that anyone who needs one can pick it up on their way out of the building rather than having to move towards the fire to reach it. Good fire extinguisher placement also means making sure they are easy to see, quick to reach and positioned close enough to each fire risk to be useful, without being so close that the fire itself would block access.
When deciding where to position your extinguishers, you should make sure that:
- Nobody has to travel more than 30 metres to reach the nearest extinguisher for Class A fires
- Extinguishers are placed near exits, on stair landings and along escape routes
- Heavier extinguishers are wall-mounted with the handle around 1 metre from the floor, and lighter ones at around 1.5 metres
- Each extinguisher is clearly signed and kept free from obstructions
- Extinguishers are positioned in the same place on each floor, so people know where to find them
- In commercial kitchens, the wet chemical extinguisher sits near the exit from the cooking area rather than directly beside the fryer
Following these points will help you meet the UK requirements for fire extinguisher placement and give everyone in the building the best chance of reaching the right extinguisher quickly.
Common Mistakes When Choosing or Positioning Extinguishers
The most common mistake is choosing extinguishers without first carrying out a fire risk assessment, which often leaves buildings with the wrong types in the wrong places. Other mistakes we regularly see include:
- Relying on a single extinguisher type to cover every risk in the building
- Placing water extinguishers in areas full of electrical equipment
- Using extinguishers as door stops or hiding them behind furniture and stock
- Forgetting to update extinguishers after a change of use, such as adding a kitchen or server room
Most of these issues are simple to fix once they are spotted, which is why regular checks and an up-to-date fire risk assessment make such a difference.
Keeping Your Extinguishers Compliant
Workplace fire extinguishers should be visually checked every month and serviced at least once a year by a competent engineer, in line with British Standard BS 5306-3. Monthly checks can be carried out by a member of staff and involve making sure each extinguisher is in place, undamaged and showing the correct pressure, while the annual service covers a full inspection of its condition and working parts. Water, foam, powder and wet chemical extinguishers also need an extended service every five years, and CO₂ extinguishers need to be overhauled every ten years, with every check and service recorded in your fire safety log book.
Staying on top of fire extinguisher maintenance protects the people in your building and keeps you on the right side of UK fire safety law. If you need help choosing, installing or servicing extinguishers for your premises, Croma Fire and Security can carry out a site survey and recommend the right types and positions for your building.
Frequently Asked Questions
Who Is Responsible for Fire Extinguishers in a Workplace?
The responsible person for fire safety is in charge of making sure the right fire extinguishers are provided, positioned and maintained, and this is usually the employer, the business owner or whoever has control of the premises. In shared buildings, such as offices with several tenants, the responsibility is often split between the landlord or managing agent for communal areas and each tenant for the space they occupy.
Do Staff Need Training to Use a Fire Extinguisher?
Employers must give staff suitable fire safety training, and anyone expected to use a fire extinguisher should be shown how to choose the right type and operate it safely. Training usually covers recognising the different extinguishers, knowing when to tackle a fire and when to leave the building, and practising the correct technique, which helps people act with confidence if a fire does break out.
How Do You Use a Fire Extinguisher?
To use a fire extinguisher, you pull out the safety pin, aim the hose or horn at the base of the fire, squeeze the handle and sweep from side to side until the fire is out, which is often remembered as the PASS method. You should always keep a clear exit behind you, stand a safe distance back from the flames, and leave the building straight away if the fire continues to grow or the extinguisher runs out.
How Long Does a Fire Extinguisher Last?
Most fire extinguishers can last for many years as long as they are serviced regularly, although they will need replacing sooner if an engineer finds damage, corrosion or a fault during a service. The manufacture date is printed on the body, and many businesses choose to replace extinguishers once they reach around 20 years old, as replacement parts become harder to source and an older unit can cost more to keep in service.
What Should You Do After a Fire Extinguisher Has Been Used?
Any fire extinguisher that has been used, even for a few seconds, should be recharged or replaced straight away, as a partly empty extinguisher may not have enough pressure to work properly the next time it is needed. You should take it out of service, put a temporary replacement in its place if possible, and record the incident in your fire safety log book.